surge arrester L71-A270X 2-electrode-arrester ordering code: b88069x2030s102 ab e / ab pm issue 05, 24.03.2004 page 1 of 2 dc spark-over voltage 1) 2) 230 ? 338 v impulse spark-over voltage at 100 v/s - for 99 % of measured values - typical values of distribution at 1 kv/s - for 99 % of measured values - typical values of distribution < 500 < 450 < 550 < 500 v v v v nominal impulse discharge current (wave 8/20 s) single impulse discharge current (wave 8/20 s) 5 10 ka ka nominal alternating discharge current (50 hz, 1 s) alternating discharge current (50 hz, 9 cycles) 5 65 a a max. follow-on current at 110 v rms 200 a peak insulation resistance at 100 v dc > 10 g ? capacitance at 1 mhz < 1.5 pf arc voltage at 1 a glow to arc transition current glow voltage ~ 22 ~ 0.5 ~ 140 v a v weight ~ 1.5 g operation and storage temperature -40 ... +90 c climatic category (iec 60068-1) 40/ 90/ 21 marking, green 270 yy o 270 - nominal voltage yy - year of production o - non radioactive 1) at delivery aql 0.65 level ii, din iso 2859 2) in ionized mode terms in accordance with itu-t rec. k.12 and din 57845/vde0845
surge arrester L71-A270X 2-electrode-arrester ordering code: b88069x2030s102 ? epcos ag 2002. reproduction, publicati on and dissemination of this data sheet, enclosures hereto and the information contained therein without epcos' pr ior express consent is prohibited. purchase orders are subject to the general conditions for t he supply of products and services of the electrical and electronics industry recommended by the zvei (german el ectrical and electronic manufacturers' association), unless otherwise agreed. ab e / ab pm issue 05, 24.03.2004 page 2 of 2 not to scale dimensions in mm non controlled document
|